Non-oil filled with connector, 0 to 10 ft range, 30 ft cable

Non-oil filled with connector, 0 to 10 ft range, 30 ft cable
Artikel-Nr.: 77065-030
Einzelpreis Kontakt

Single point calibration - zero cal only

Robust Sensor

Streamlined Design

Minimal Sensor Fouling

Greater Directivity

Technische Daten

Abmessungen (H x B x T): 23 mm x 38 mm x 135 mm
Allowable Level: Standard: 10.5 m (34.5 ft)
Extended: 31.5 m (103.5 ft)
Bestimmungsgrenze: 0 to 10 ft range
Betriebsbedingungen: 0 - 70 °C
Genauigkeit: LEVEL MEASUREMENT: ±0.16% full scale ±1.5% of reading at constant temp (±2.5ºC) ±0.20% full scale ±1.75% of reading from 0 to 30ºC (32 to 86ºF); ±0.25% full scale ±2.1% of reading from 0 to 70ºC (32 to 158ºF)
  Velocity-Induced Depth Error Compensated based on flow velocity
  VELOCITY MEASUREMENT: ±2% of reading or 0.05 fps** **Uniform velocity profile, known salinity, positive flow. Field performance is site specific.
Gewährleistung: 6 Monate
Kabel: Urethane sensor cable with air vent
Kabellänge: 30 ft
Kompatible Geräte: 920, 930, 930T, 950, 900 Max Samplers, FL1500 and AV9000 Interface Analyzer Module for FL900 and AS950
Level Accuracy: ±0.16% full scale ±1.5% of reading at constant temp (±2.5ºC)
±0.20% full scale ±1.75% of reading from 0 to 30ºC (32 to 86ºF)
±0.25% full scale ±2.1% of reading from 0 to 70ºC (32 to 158ºF)
Level Measurement Method: Differential pressure transducer with stainless steel diaphragm and atmospheric pressure reference
Material: Noryl outer shell with epoxy potting within
Messbereich (2): -1,52 m/s - 6,10 m/s
Messmethode: LEVEL: Pressure transducer with stainless steel diaphragm
Oil or Non-Oil Filled: Non-oil filled with connector
Spezielles Ausstattungsmerkmal: Non-oil Filled, 30 ft cable
Tiefe: Typical Minimum Operating Depth: 2 cm
Typical Minimum Operating Depth: 2 cm (0.8cm)
Velocity Accuracy: ±2% of reading or 0.05 fps**
**Uniform velocity profile, known salinity,
positive flow. Field performance is site specific.
Velocity-Induced Depth Error: Compensated based on flow velocity
Velocity Measurement Method: Doppler ultrasonic;
twin 1 MHz piezoelectric crystals