TSS EX1 sc TriClamp Hach

TSS EX1 sc TriClamp Hach
Artikel-Nr.: LXV328.99.20002
Einzelpreis Kontakt
Lieferung innerhalb von 2 Wochen

Unique Multi-Beam Pulsed Infrared Light System

TSS sc probes have a double optical system with two pulsating infrared LEDs and four receivers. This combined multiple beam alternating light method with beam focusing facilitates accurate color independent measurement of turbidity from 0.001 to 4,000 FNU and suspended solids from 0.001 to 500 g/l.

Automatic Compensation for Air Bubbles and Temperature Swings for Accuracy

Special software enables the system to recognize gas bubbles or temperature swings for a more accurate suspended solids or turbidity measurement.

Standard Compliant and Precise - Ease of Calibration

The turbidity measurement complies with the standard DIN EN 27027 (ISO 7027). Calibration is not necessary. If the probe is used to measure the solids content, a one-point calibration suffices. For special applications, curves can be defined using several calibration points.

Withstands Difficult Conditions and Harsh Environments

Probes are made of highly polished stainless steel with a scratch resistant sapphire window. They are design to withstand harsh environments and keep particles from sticking to the surface.

Suitable for Use in Potentially Explosive Atmospheres

TSS EX1 sc probes have been specially designed for measurement in hazardous locations with Class I Div 2 requirements.

Inhalt

Turbidity & Suspended Solids sensor, user manual

Technische Daten

Ansprechzeit: 1 - 300 s adjustable
  1 s < T90 < 300 s (adjustable)
Anwendung: Hazardous locations
Automatischer Wischer: Nein
Betriebsbedingungen: -10 - 50 °C
Druckbereich: 10 bar or 100 m
Durchfluss: Max. 3 m/s (the presence of air bubbles affects the measurement)
Durchmesser: 48.5 mm
Genauigkeit: Turbidity up to 1000 FNU/NTU: < 5 % of measurement value or ±0.01 NTU, whichever is greater
Gewährleistung: 24 Monate
Gewicht: ca, 1,6 kg
Inhalt: Turbidity & Suspended Solids sensor, user manual
Installationsbauform: Ball Valve Insertion
Kabellänge: 10 m
Kalibriermethode: Turbidity Formazin or Stablcal Standard (at 800 NTU). Requires a calibration kit.
Suspended Solids Sample specific, based on gravimetric analysis with a correction factor procedure.
Kalibrierung: Turbidity (TRB): Factory calibrated
Solids (TS): To be calibrated by customer on site
Zero point: Permanently calibrated in the factory
Kompatibilität Controller: SC200, SC1000, SC4500. All controllers sold separately
Länge: 448 mm
Lieferumfang: Turbidity & Suspended Solids sensor, user manual
Material: Edelstahl DIN 1.4571;Kabelverschraubung-Edelstahl 1.4305
Maximale Temperatur: 50 °C
Messbereich: Trübung (TRB)): 0,001 - 9999 FNU
Feststoffe (TS): 0.001 - 500 g/L
Messmethode: Kombiniertes Mehrstrahl-Wechsellicht-Verfahren mit IR-Diodensystem und Strahlfokussierung,
Trübung (TRB): 2-Kanal-90° Streulichtmessung entsprechend DIN/EN 27027/ISO 7027,Wellenlänge = 860 nm
Feststoff (TS): Streulichtmessung bei 120°,Wellenlänge = 860 nm
Modell: TSS EX1 sc
Montagearten: TriClamp
Parameter: Turbidity, Suspended Solids
Spezielles Ausstattungsmerkmal: With Triclamp
Umgebungstemperatur: 0 - 50 °C
Wartungs-Intervall: 1 h/Monat
Wiederholbarkeit: TS-Gehalt: < 4 %
Trübung < 3 %